臺(tái)灣標(biāo)準(zhǔn)電機(jī)SEW儀器儀表--1805 ER Earth Resistance Testers 3 Wire Analog

        
     
    1805 ER   Earth Resistance Testers
    3 Wire (Analog)  
    1805 ER
    FEATURES
     
     High quality Tau Band movement.
     Capable of measuring earth voltage (Vac).
     2mA measuring current permits earth resistance tests with tripping earth leakage current breakers in the circuit under test.
     Test leads are supplied as standard accessories for simplified two-wire measuring system.
     Battery operated.
     Battery life indication.
     CAT III 150V.
     Calibration performed with supplied test leads.
     WHY "GROUNDING TEST" IS NECESSARY
     "Grounding" has a few different purposes, such as for safety and for the stability of the electrical circuits. Listed below is more info about it.
     1. Power system to the ground: As shown in figure, the purpose is preventing the secondary side from the damage of the primary side. It's necessary for user's safety.
     2. Equipment to the ground: Connect equipments or shells to the ground. The purpose is protecting the user from the leakage of the equipments.
     3. Electrical signal to the ground: Set up a "Zero volt" reference point or a loop path for all different signals. The purpose is for correct action or measuring.
     4. Grounding for shielding: Top prevent static electricity. To prevent noise, electromagnetic interference (put shielding). Shielding room, cable and communication wires to the ground, equipment's guard terminals to the ground, power transformers and filters to the ground.
    SPECIFICATIONS
     
    Measuring Ranges Earth Resistance : 0-10 Ohm/0-100 Ohm/0-1000 Ohm
    Earth Voltage : 0-30V AC (40-500Hz)
    Accuracy Earth Resistance : +/- 3% of full scale
    Earth Voltage : +/- 2.5% of full scale
    Measuring System Earth resistance by constant current inverter (Square Signal) 820 Hz approx. 2mA
    Open Circuit Indication LEDunit
    Power Source 1.5 V (AA) x 8
    Dimensions 170(L) x 165(W) x 92(D) mm
    Weight Approx. 1000g (battery included)
    Accessories Test leads (AL-36 : red-15m, yellow-10m, green-5m)
    Auxiliary earth spikes
    Simplified measurement probe
    Heavy-duty case
    Shoulder belt
    Instruction manual
    batteries
    特 點(diǎn)
    ● 吊線式高品質(zhì)防震錶頭。
    ● 可量測(cè)接地電阻(Ω)和接地電壓(ACV)。
    ● 量測(cè)電流僅有2mA,不會(huì)影響漏電斷路器的跳脫。
    ● 可作三線式量測(cè)或兩線式量測(cè)。
    ● 電池電量指示。
    ● 使用電池操作。
    ● 請(qǐng)使用提供的測(cè)試線測(cè)試

    CAT III 150V
    規(guī) 格 (23°C±5°C <80%R.H.)
    量測(cè)檔位 接地電阻 : 0-10Ω/0-100Ω/0-1000Ω
    接地電壓 : 0-30V AC(40-500Hz)
    準(zhǔn)確度 接地電阻 : ±3%滿刻度
    接地電壓 : ±2.5%滿刻度
    量測(cè)系統(tǒng) 820Hz 2mA 定電流
    接線正確(量測(cè)接地電阻) 紅燈(LED)會(huì)亮著
    外形尺寸 170(長(zhǎng))×165(寬)×92(高)mm
    重量 約1000公克(含電池)
    使用電池 1.5V(AA)×8(顆)