HPF HIGH PASS FILTER
Description
HPF filters are specially designed to remove harmonics from the current absorbed by 6 pulse power converters, such as frequency converters for motors, UPS, welding equipment, etc. They are essentially passive filters based on a series parallel combination of inductance and capacitors. (Main function is to filter the 5th and 7th current harmonic and to decrease the level of the 11th and 13th current harmonics). With these HPF filters we will be able to get a reduction of the THD (I) level higher than a simple input reactor reduction, decreasing THD (I) to values below 8%. At full load conditions the THD (I) becomes lower than 5%.
Options
Kit regulación sobre-compensación/Overcorrection regulating Kit
Kit de medida/Measuring kit
Technical Characteristics
Tensión nominal/Rated voltage .........................................................................400 ~ 480 V
Frecuencia/Frequency .........................................................................................50/60 Hz
Corriente RMS de carga (Ic)/RMS load current (Ic) ......................................4 ... 1000 A
Máx. sobrecarga /Max. ooverload ..........................................................................................1min. a 1,5 Ic
Corriente RMS filtrado (If)/Filtered RMS current (If)........................................1.6 ... 72 A
THD residual/THD residual current ...................................................................Aprox. 8%
Caída de tensión a In/Voltage drop at In................................ ......................< 2%
Construcción/Construction ...................................................................................Armario metálico/Metal cabinet
Grado de protección/Protection degree ........................................................
Color/Colour .........................................................................................................Gris RAL 7035
Instalación/Installation .........................................................................................Interior/Indoor
Montage/Assembly ...............................................................................................Tipo A/B: Mural, Tipo C/D: Sobre suelo
A/B type: Wall mounting, C/D type: Floor mounting
Normas/Standards ..............................................................................................
Part number |
RMS load current(A) |
Filtered RMS
current (A) |
Voltage(V) |
Frequency (Hz) |
Cabinet |
Price() |
50 Hz |
|
HPF140009 |
9 |
3.6 |
400/415 |
50 |
A |
On request |
HPF140016 |
16 |
6.4 |
400/415 |
50 |
A |
HPF240022 |
22 |
8.8 |
400/415 |
50 |
A |
HPF240032 |
32 |
12.8 |
400/415 |
50 |
A |
HPF240040 |
40 |
16 |
400/415 |
50 |
A |
HPF240047 |
47 |
18.8 |
400/415 |
50 |
B |
HPF240054 |
54 |
21.6 |
400/415 |
50 |
B |
HPF340064 |
64 |
25.6 |
400/415 |
50 |
B |
HPF340076 |
76 |
30.4 |
400/415 |
50 |
B |
HPF340090 |
90 |
36 |
400/415 |
50 |
C |
HPF340110 |
110 |
44 |
400/415 |
50 |
C |
HPF440150 |
150 |
60 |
400/415 |
50 |
C |
HPF440180 |
180 |
72 |
400/415 |
50 |
C |
|
... 400 |
|
|
|
D |
|
|
|
|
|
|
|
60 Hz |
|
HPF146009Z |
9 |
3.6 |
460/480 |
60 |
A |
On request |
HPF146016Z |
16 |
6.4 |
460/480 |
60 |
A |
HPF246022Z |
22 |
8.8 |
460/480 |
60 |
A |
HPF246032Z |
32 |
12.8 |
460/480 |
60 |
A |
HPF246040Z |
40 |
16 |
460/480 |
60 |
A |
HPF246047Z |
47 |
18.8 |
460/480 |
60 |
B |
HPF246054Z |
54 |
21.6 |
460/480 |
60 |
B |
HPF346064Z |
64 |
25.6 |
460/480 |
60 |
B |
HPF346076Z |
76 |
30.4 |
460/480 |
60 |
B |
HPF346090Z |
90 |
36 |
460/480 |
60 |
C |
HPF346110Z |
110 |
44 |
460/480 |
60 |
C |
HPF446150Z |
150 |
60 |
460/480 |
60 |
C |
HPF446180Z |
180 |
72 |
460/480 |
60 |
C |
|
... 400 |
|
|
|
D |
Other current, voltages and frequencies available on request. Loads which need an instantaneus correction available on request.
|
Harmonic filters
HAF, HPF
HAF ABSORPTION FILTER
HPF140004 HPF146004Z
HPF140009 HPF146009Z
HPF140016 HPF146016Z
HPF240022 HPF246022Z
HPF240032 HPF246032Z
HPF240040 HPF246040Z
HPF240047 HPF246047Z
HPF240054 HPF246054Z
HPF340064 HPF346064Z
HPF340076 HPF346076Z
HPF340090 HPF346090Z
HPF340110 HPF346110Z
HPF440150 HPF446150Z
HPF440180 HPF446180Z
Harmonic Filters
These filters are used when the main objective is not the reactive power compensation at the fundamental frequency, but to reduce the harmonic distortion in the supply system.
Among the problems caused by harmonics and which may make their suppression necessary, are the following:
Interferences in telecommunications.
Distortion on the mains voltage.
Disturbances in electronic systems.
Erratic operation of control and protection relays .
Failures in transformers and motors, due to overheating caused by losses on the core.
Overheating of protective fuses to the point where a minor spike on the line causes them to blow.
It should be pointed out that the impedance of all the filters is capacitive below its tuning frequency, whereby they also contribute, even if in a small scale, to the reactive power compensation at the fundamental frequency.
Installation of filters produces a modification on the topology of the electrical supply system. For this reason, the design of filters must be done with regard to an accurate analysis and study of the whole system.
According to the application, there are different types of filters:
3rd harmonic filter HBF-T
Isolation filter
Absortion filter HAF
High pass filter HPF
Active filter SINAF 2.0
|
|